Basic Information |
|
Part Number |
02353AFX-002
|
Model |
USG6525E-AC
|
Description |
USG6525E AC Host(2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power)
|
First supported version |
V600R007C20SPC600
|
Technical Specifications |
Installation Type |
Rack,Work bench
|
Cabinet installation standard |
Cabinet with a depth of 600 mm or above
|
Wide [mm] |
442 mm
|
Depth [mm] |
420 mm
|
Height [mm] |
43.6 mm
|
Chassis height [U] |
1
|
Weight without packaging [kg(lb)] |
5.95 (13.12)
|
Weight with packaging [kg(lb)] |
7.93 (17.48)
|
Maximum power consumption [W] |
45.3
|
Maximum heat dissipation [BTU/hour] |
154.4
|
Heat dissipation mode |
The fan module locates at the air exhaust of the system.
|
Power supply mode |
AC built-in
|
Rated input voltage [V] |
100 V to 240 V, 50 Hz/60 Hz
|
Input voltage range [V] |
90 V to 290 V, 47 Hz to 63 Hz
|
CPU |
1 CPU, 4 cores/CPU, up to 1.4 GHz
|
Memory |
DDR4 4 GB
|
NOR Flash |
32 MB
Note: The specification of the NOR flash of the device to be delivered is 64 MB. You can run the display version command to view the NOR flash memory specification of a device.
|
NAND Flash |
2 GB
|
Hard disk |
Optional. M.2 SSD (64GB/240GB), hot-swappable.
|
Redundant power supply |
Two power modules are supported for 1+1 power redundancy.
|
Number of power modules |
1
|
Number of fan modules |
1
|
Types of fans |
Pluggable
|
Airflow direction |
Air inlet from front and air outlet from rear
|
Long-term operating temperature [°C(°F)] |
0°C to 45°C
|
Storage temperature [°C(°F)] |
-40°C to 70°C
|
Long-term operating relative humidity [RH] |
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH] |
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)] |
0 m to 5000 m
|
Storage altitude [m(ft.)] |
0 m to 5000 m
|
MTBF [year] |
68.98
|
MTTR [hour] |
2
|
Console port |
RJ45
|
Eth Management port |
RJ45
|
Maximum number of 10GE ports |
2
|
Maximum number of GE ports |
8
|