Basic Information |
|
Part Number |
98012053
|
Model |
S5735-S48P4XE-V2
|
Description |
S5735-S48P4XE-V2 (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, 2*12GE stack ports, PoE+, without power module)
|
Technical Specifications |
Height [mm] |
43.6 mm
|
Depth [mm] |
420.0 mm
|
Wide [mm] |
442.0 mm
|
Chassis height [U] |
1
|
Weight without packaging |
6.94 kg (15.30 lb)
|
Weight with packaging |
8.88 (19.58)
|
Typical power consumption [W] |
54.51
|
Maximum power consumption [W] |
- Without PoE: 105.90 W
- Full PoE load: 1931.44 W (PoE: 1680 W)
|
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Typical heat dissipation [BTU/h] |
185.99
|
Maximum heat dissipation [BTU/h] |
- Without PoE: 361.34
- Full PoE load: 6590.27
|
Power supply mode |
Pluggable power supply
|
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45–65 Hz
- High-voltage DC input: 190 V DC to 290 V DC
- DC input: -38.4 V DC to -72 V DC
|
Rated input voltage [V] |
- AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz
- High-voltage DC input: 240 V DC
- DC input: –48 V DC to –60 V DC
|
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.
|
Number of card slots |
0
|
Number of power slots |
3
|
Memory |
2 GB
|
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command.
|
Redundant power supply |
1+1+1
Pluggable AC and DC power modules can be used together on the same device.
|
Types of fans |
Built-in
|
Noise at normal temperature (acoustic power) |
Three 600 W AC PoE power modules with 30% load: 50 dBA
Three 1000 W AC PoE power modules with 30% load: 49.9 dBA
Three 1000 W DC PoE power modules with 30% load: 48.5 dBA
|
Noise at normal temperature (acoustic pressure) |
Three 600 W AC PoE power modules with 30% load: 38 dBA
Three 1000 W AC PoE power modules with 30% load: 37.9 dBA
Three 1000 W DC PoE power modules with 30% load: 36.5 dBA
|
Airflow direction |
Air intake from left, front, and right and air exhaust from rear
|
Restriction on the operating temperature variation rate |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F).
|
Long-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing)
|
Long-term operating altitude |
0–5000 m (0–16404 ft.)
|
Storage altitude |
0-5000 m (0-16404 ft.)
|
MTBF [year] |
79.02
|
MTTR [h] |
2
|
Availability |
>0.99999
|
Maximum number of physical ports on the entire device |
54
|
Maximum number of 100GE ports |
0
|
Maximum number of 40GE ports |
0
|
Maximum number of 25GE ports |
0
|
Maximum number of 10GE ports |
4
|
Maximum number of GE ports |
52
|
Maximum number of FE ports |
48
|
10GE optical interface |
4
|
1000M electrical interface |
48
|
USB |
Supported
|
Console port |
RJ45
|
Eth Management port |
Not supported
|
Service port surge protection |
Common mode: ±6 kV
|
Power supply surge protection |
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
- Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
|
RPS input |
Not supported
|
PoE |
Supported
|
PoE power supply |
Supported
|